===== What can be imported? ===== | ===== What can be imported? ===== | ||
Using the tool, image data can be imported as dark-subtracted and gain-corrected images, or as dark-subtracted images only (in this case a separate gain reference file should be provided). Optionally, combinations of raw image stacks, drift-corrected stacks, and drift-corrected and averaged 2D images, can be imported simultaneously. | Using the tool, image data can be imported as dark-subtracted and gain-corrected images, or as dark-subtracted images only (in this case a separate gain reference file should be provided). Optionally, combinations of raw image stacks, drift-corrected stacks, and drift-corrected and averaged 2D images, can be imported simultaneously. | ||
+ | |||
+ | ===== How do I import images from EPU's file structure? ===== | ||
+ | EPU is the automated data acquisition software from FEI / ThermoFisher. EPU saves recorded movies grouped by the grid-square that the images were recorded from. EPU creates for each grid-square one sub-folder, and within a subfolder called " | ||
+ | If you activate the button " | ||
+ | |||
+ | ===== How do I import images from other file structures ? ===== | ||
+ | If you do not activate the button " | ||
===== Processing imported images ===== | ===== Processing imported images ===== | ||
The Import Tool allows a choice of scripts to be run on the imported data during import, which results in sequential processing of the data. This is required, e.g., if the incremental electron dose on the sample has to be computed for consecutively recorded image stacks within the same dose-fractionated tomography tilt series. The Import Tool also allows a choice of scripts to be submitted to the parallel batch queue for processing after import. This would be used, e.g., to schedule computationally intensive tasks such as motion correction and the subsequent steps. | The Import Tool allows a choice of scripts to be run on the imported data during import, which results in sequential processing of the data. This is required, e.g., if the incremental electron dose on the sample has to be computed for consecutively recorded image stacks within the same dose-fractionated tomography tilt series. The Import Tool also allows a choice of scripts to be submitted to the parallel batch queue for processing after import. This would be used, e.g., to schedule computationally intensive tasks such as motion correction and the subsequent steps. |